Quantitative flow ratio virtual pullback index predicts focal coronary artery disease identified on wire-based pullback pressure gradient
Z. Teoh, Thomas Wardill, Michael Zhang, Joseph M O'Brien, Derek P. Chew, B. Ko, D. Wong
2026.4.26World Journal of Cardiology
Paper details
- Journal
- World Journal of Cardiology
- Published
- 2026.4.26
- Citations
- 0
- References
- 20
- Fields
- Coronary Interventions and Diagnostics, Cardiac Imaging and Diagnostics, Cerebrovascular and Carotid Artery Diseases
Abstract
BACKGROUND Wire-based pressure pullback gradient (PPG) is the reference method for differentiating focal from diffuse coronary artery disease (CAD). However, it requires invasive instrumentation and hyperaemia. The quantitative flow ratio (QFR)-derived PPG [QFR virtual pullback (QVP) index] is a non-invasive alternative. AIM To evaluate the correlation between QVP index and PPG, and to explore the diagnostic performance of QVP index for identifying focal CAD. METHODS We retrospectively studied 74 patients (86 vessels) who underwent coronary angiography, fractional flow reserve (FFR), wire-based PPG, angio-based QFR and QVP index between December 2021 and October 2023. The primary analysis focused on FFR-significant lesions (FFR ≤ 0.75, n = 31), as these are clinically relevant for guiding percutaneous coronary intervention. QVP index was calculated from the maximal QFR drop over 20 mm and the length of the epicardial segment with the greatest reduction. Focal disease was defined by PPG > 0.73. RESULTS QFR was strongly correlated with FFR (r = 0.84, P < 0.001). In FFR significant vessels (FFR ≤ 0.75, n = 31), QVP index showed a moderate correlation with PPG (r = 0.45, P = 0.01). QVP index demonstrated excellent intra-observer and inter-observer variability with intraclass correlation coefficients of 0.918 (P < 0.001) and 0.932 (P < 0.001), respectively. QVP index predicted focal disease (defined as PPG > 0.73) with area under the curve of 0.73 (P = 0.02). A retrospectively derived threshold of QVP index > 0.53 yielded 90% sensitivity and 53% specificity (P = 0.04), though this cut-off was derived from the same dataset and should be regarded as hypothesis-generating. CONCLUSION QVP index correlates with PPG in FFR-significant lesions and may help to identify focal CAD patterns. However, these findings are hypothesis-generating and derived from a small, retrospective, single-centre cohort without external validation. Prospective multicentre studies are needed to validate cut-offs and determine whether QVP index provides incremental clinical value beyond existing physiological and imaging tools.
Citation format
TEOH, Z., et al. Quantitative flow ratio virtual pullback index predicts focal coronary artery disease identified on wire-based pullback pressure gradient. World Journal of Cardiology, 2026, 18(4).