Electrochemical sensors and biosensorsAnalytical Methods in PharmaceuticalsPharmacological Effects and Toxicity Studies

H. Jalilzadeh, Bahareh Feyzi-barnaji, Ali Mohammadi, M. Amanlou, Niayesh Mohebbi

2026.3.2JOURNAL OF ANALYTICAL CHEMISTRY

DOI: 10.1134/s1061934825600982

Resumen

Gabapentin (GB) is commonly used as an anti-epilepsy medication. Electrochemical sensing has been shown to be a promising method for drug detection at very low concentrations. In the present study, for the first time, electrochemical detection of GB was directly conducted using a modified glassy carbon electrode based on graphene oxide and gold nanoparticles. The limit of detection and limit of quantitation of the method were found to be 0.08 and 0.24 μM, respectively, by means of the differential pulse voltammetry technique. The sensor was characterized via scanning electron microscopy, energy-dispersive X-ray spectroscopy, and transmission electron microscopy. The reproducibility, selectivity, stability, and repeatability of the modified electrode were found to be acceptable. The developed modified electrode demonstrated excellent performance for the detection of GB in standard solutions as well as in serum and saliva samples.

Formato de cita

JALILZADEH, H., et al. A nanodevice based on graphene oxide for the direct determination of gabapentin in spiked saliva and serum samples. JOURNAL OF ANALYTICAL CHEMISTRY, 2026, 81(2): 356–365.