Medicine

Yen-Chih Chen, M. Hsiao, Yi-Chian Wang, Chih-Pin Fu, Tyng-Guey Wang

2017.2.16Journal of Medical Ultrasound

DOI: 10.1016/j.jmu.2017.01.002

tlooto Summary

Submental ultrasonography is a reliable and accurate method for assessing the hyoid bone movement during swallowing through the assessment of inter- and intrarater reliability and its accuracy is examined by comparing the results with videofluoroscopic swallowing study (VFSS.

Abstract

Background Timely and adequate laryngeal elevation along with hyoid bone movement is an essential component of the swallowing movement under normal physiological conditions. The purpose of this study was to verify the reproducibility of using ultrasonography to evaluate hyoid bone displacement during swallowing through the assessment of inter- and intrarater reliability and examine its accuracy by comparing the results with videofluoroscopic swallowing study (VFSS). Methods A self-designed water balloon was fixed to the transducer, which provided good contact between the transducer and the submental skin. Ten participants with dysphagia were recruited. The measurements of hyoid bone displacement using ultrasonography were performed by two of the authors. All the participants underwent ultrasonographic examinations and VFSS within 24 hours. Results The intrarater intraclass correlation coefficient (ICC) of the two examiners was 0.996 and 0.959, respectively (p < 0.01); the interrater ICC between the two examiners was 0.892 (p < 0.05). ICCs between VFSS and ultrasonography for two researchers were 0.815 and 0.916 (p < 0.01). Conclusion Submental ultrasonography is a reliable and accurate method for assessing the hyoid bone movement.

Citation format

CHEN, Yen-Chih, et al. Reliability of ultrasonography in evaluating hyoid bone movement. Journal of Medical Ultrasound, 2017, 25: 90–95.