A. Minkovsky, Mark N Lee, M. Dowlatshahi, Trevor E. Angell, Lilian S Mahrokhian, A. Petrides, Stacy E. F. Melanson, E. Marqusee, W. Woodmansee
2016.10.10AACE Clinical Case Reports
tlooto Summary
The case report demonstrates that ingestion of high dose biotin in multiple sclerosis patients can cause interference with laboratory assessment of thyroid function, which causes laboratory values suggestive of thyrotoxicosis and can lead to unnecessary evaluation.
Abstract
OBJECTIVE To review cases and increase awareness in clinicians treating patients who may be taking biotin.
METHODS We describe the presentation and workup of a woman with secondary progressive multiple sclerosis on high dose biotin with laboratory studies suggestive of thyrotoxicosis.
RESULTS Plasma samples showed laboratory evidence of elevated thyroid hormone levels with elevated free thyroxine >7.8 ng/dl (reference interval (RI) 0.9-1.7 ng/dl) and decreased thyroid stimulating hormone <0.02 uIU/ml (RI 0.50-5.70 uIU/ml). Laboratory values normalized when biotin was withheld prior to repeat testing.
CONCLUSIONS Our case report demonstrates that ingestion of high dose biotin in multiple sclerosis patients can cause interference with laboratory assessment of thyroid function. This interference causes laboratory values suggestive of thyrotoxicosis and can lead to unnecessary evaluation. Clinicians should be aware of the risk of laboratory interference in this patient demographic.
Citation format
MINKOVSKY, A., et al. HIGH-DOSE BIOTIN TREATMENT FOR SECONDARY PROGRESSIVE MULTIPLE SCLEROSIS MAY INTERFERE WITH THYROID ASSAYS. AACE Clinical Case Reports, 2016, 2: e370-e373.