EngineeringEnvironmental Science

C. Hagentoft, A. S. Kalagasidis, B. Adl-Zarrabi, S. Roels, J. Carmeliet, H. Hens, J. Grunewald, Max Funk, R. Becker, Dina Shamir, O. Adan, H. Brocken, K. Kumaran, R. Djebbar

2004.4.1Journal of Building Physics

DOI: 10.1177/1097196304042436

Abstract

The standardised Glaser method for calculation, prediction and evaluation of moisture performance is considered as rarely applicable. The present state of knowledge, analytical as well as experimental, concerning heat, air and moisture demands updating of standards. This paper presents five numerical benchmark cases for the quality assessment of simulation models for one-dimensional heat, air and moisture (HAM) transfer. In one case, the analytical solution is known and excellent agreement between several solutions from different universities and institutes is obtained. In the remaining four cases, consensus solutions have been found, with good agreement between different HAM models. The work presented here is an outcome of the EU-initiated project for standardisation of HAM calculation methods (HAMSTAD WP2).

Citation format

HAGENTOFT, C., et al. Assessment method of numerical prediction models for combined heat, air and moisture transfer in building components: Benchmarks for one-dimensional cases. Journal of Building Physics, 2004, 27: 327–352.