Agricultural and Food SciencesBiology

Total protein determination in pigeon plasma and serum: comparison of refractometric methods with the biuret method

J. T. Lumeij, B. Maclean

1996.1.16JOURNAL OF AVIAN MEDICINE AND SURGERY

tlooto Summary

Total protein concentration established by the biuret method in plasma and serum from pigeons was compared with results obtained by temperature-compensated and nontemperature-com- pensated refractometers in plasma.

Abstract

Total protein concentration established by the biuret method in plasma and serum from pigeons was compared with results obtained by temperature-compensated and nontemperature-com- pensated refractometers in plasma. Plasma total protein concentration and serum total protein con- centration measured by the biuret method were highly correlated (r = 0.99); plasma values were on average 1.74 g higher than serum values because of the presence of fibrinogen. Values obtained by refractometer were higher than values obtained by the biuret method. Values obtained by the temperature-compensated refractometer were significantly higher than those obtained by the non- temperature-compensated refractometer and were not considered to be accurate. Plasma protein concentration measured by refractometer can only be considered a rough estimate of total protein concentration obtained by the biuret method (r = 0.89) after applying a correction formula for the species and specific refractometer.

Citation format

LUMEIJ, J. T.; MACLEAN, B. Total protein determination in pigeon plasma and serum: Comparison of refractometric methods with the biuret method. JOURNAL OF AVIAN MEDICINE AND SURGERY, 1996, 10: 150–152.