J. Brown, S. C. Macleod, C. Macnaughtan, Margery A. Smith, B. Smyth
1968.9.1JOURNAL OF ENDOCRINOLOGY
tlooto Summary
A rapid laboratory procedure for measuring total estrogens in urine was developed and is described, and it is revealed that the short procedure was the more reliable method at levels below 5 mcg/24-hour urine.
Abstract
SUMMARY A semi-automatic extractor was developed which processes 12 urines at a time to a stage where 'total' oestrogens can be measured by colorimetry using the Kober reaction (late pregnancy urines) or by fluorimetry using the Kober—Ittrich procedure (non-pregnancy and early pregnancy urines). One worker can complete 12 analyses in 31⁄2 hr. or 24–36 in a working day. The results obtained at oestrogen levels above 1 mg./24-hr. urine were the same as those obtained by a method specific for oestriol. The results obtained from non-pregnancy urines were compared with the sums of oestriol, oestrone and oestradiol obtained by the method of Brown (1955). The mean ratio (± s.d. ) of the two values was 1·22 ± 0·31. The comparisons indicated that the short procedure was the more reliable method at levels below 5 μg./24-hr. urine. Values for normal subjects are given. The methods appear to be entirely suitable for assessing oestrogen production by the ovaries, testes, adrenals and placenta.
Citation format
BROWN, J., et al. A RAPID METHOD FOR ESTIMATING OESTROGENS IN URINE USING a SEMI-AUTOMATIC EXTRACTOR. JOURNAL OF ENDOCRINOLOGY, 1968, 42: 5–15.