Y. Kolbas, Ya.S. Pyatnitskii, M.I. Rodionov, I. I. Saveliev

2022.2.1QUANTUM ELECTRONICS

DOI: 10.1070/qel17991

tlooto Summary

Experimentally studied output characteristic of four-frequency Zeeman laser gyroscope with alternating frequency bias and compared to two-frequency ZLG.

Abstract

We have experimentally studied the output characteristic of a four-frequency Zeeman laser gyroscope (ZLG) on longitudinal modes with orthogonal circular polarisations having an alternating frequency bias and compared it with the output characteristic of a two-frequency ZLG. It is shown that by representing a four-frequency ZLG as a set of two-frequency ZLGs with orthogonal polarisations, the output characteristic of a four-frequency ZLG can be obtained through the arithmetic mean of the output characteristics of the same gyroscope. The experimental output characteristic of a four-frequency ZLG with an alternating bias in the form of a meander with a switching frequency of 1 kHz, as well as its combination with a low-frequency meander with a frequency of 1 Hz, is presented. The efficiency of using slow meander modulation for the linearization of the output characteristic of a four-frequency ZLG is demonstrated.