Abstract
This paper presents the design and implementation of a low-cost, dual-master, four-degree-of-freedom (4-DOF) bilateral teleoperated robotic arm specifically for acupuncture applications. The architecture employs a spatial positioner for 0.5× scaled alignment and a sliding potentiometer-based incisioner for collinear needle motion, with all control conducted in open loop (no PID or feedback compensation). The system leverages a Teensy 4.0 microcontroller, PCA9685 PWM expander, and hobby-grade servos for both the master interface and the slave manipulator. Experimental validation demonstrates effective positional repeatability, low-latency teleoperation, and sufficient precision for simulated acupuncture, making the platform suitable for cost-sensitive clinical training or remote therapy research.
Introduction
Teleoperated robotic systems are critical for extending human capabilities into hazardous, delicate, or inaccessible environments. In particular, the integration of robotics into traditional therapeutic domains such as acupuncture offers substantial promise for enhancing precision, remote access, and operator safety. However, most existing medical teleoperation solutions rely on expensive sensors and closed-loop controllers, making them prohibitive for adoption in resource-constrained contexts or targeted training scenarios.
Bilateral teleoperation systems—where operator input on a master interface is mapped to a remote slave robot—are increasingly shaped by advances in interface design, control strategy, and the integration of haptic and visual feedback. Recent works emphasize the value of dual-master configurations, wherein separate control devices govern spatial alignment and task-specific actions, affording improved operator ergonomics and system modularity[1]. Most state-of-the-art platforms, especially those developed for surface conditioning and dexterous manipulation, implement sophisticated feedback or haptic overlays to optimize precision and user experience[2][3]. Nevertheless, there is a growing research need to explore simplified, open-loop architectures that can deliver sufficient accuracy without the cost and complexity of advanced sensing and feedback[4].
This research describes a system purposely omitting PID or feedback control: a dual-master, 4-DOF teleoperated robotic arm for acupuncture, utilizing inexpensive potentiometers for positional encoding and servo actuation[4]. The architecture is designed for reproducibility, robustness under typical latency, and maximal accessibility, guided by the principle that technological simplification can unlock broader impact, mirroring calls for multidisciplinarity and practical innovation in medical telerobotics[5].
System Architecture
A. Hardware Overview
The proposed system comprises a dual-master interface and a single-arm slave manipulator. The master interface consists of two operative sub-systems:
- Spatial Positioner: An analog gimbal device senses planar (x,y) translation, stylus rotation (yaw), and a base rotation, each tracked by individual rotary potentiometers. All axes are subject to a fixed 0.5× scaling to reduce operator error and enhance safety during transfer onto the slave manipulator.
- Sliding Potentiometer Incisioner: A linear track equipped with a potentiometer registers depth along the insertion (z-axis) trajectory, providing direct and intuitive mapping for needle collinear motion.
The control core uses a Teensy 4.0 microcontroller with an integrated ADC for analog readout. PWM signals are generated via a PCA9685 expander board, providing independent 12-bit resolution actuation for up to 16 channels; four are used for the slave's actuators.
On the slave side, the manipulator consists of four standard hobby servos (MG996R or equivalent) for base rotation, shoulder pitch, elbow pitch, and vertical needle actuation. The frame is fabricated from cost-effective acrylic and aluminum, emphasizing assembly simplicity and lightweight design.
B. Control Scheme
The system deliberately avoids closed-loop feedback, PID controllers, or encoders. Instead, analog readings from the potentiometers (0–1023 range) are mapped linearly to each servo's angular range, with the mapped value halved to achieve the desired 0.5× spatial scaling:
PWM=(1023Input)×(MaxPWM−MinPWM)+MinPWM
The Teensy 4.0 microcontroller transmits the commands to the PCA9685 over I\textsuperscript{2}C. The open-loop architecture places the onus of accuracy on the operator, relying on visual feedback for correction rather than closed-loop compensation. While force sensing and haptic feedback are recognized as beneficial in prior literature[3][6], the present design restricts itself to vision-only guidance in pursuit of minimalism and accessibility[4].
C. Dual-Master Mapping
In alignment with recent innovations in teleoperation interfaces[1], this system divides control into a spatial positioner for 3-DOF alignment and a separate incisioner for collinear movement. Such dual-master architectures are shown to improve ergonomic separation and can simplify user training[1].
Experimental Results
A. Methods
Validation focused on spatial precision, latency, and ergonomic assessment. Tests employed a synthetic gel model simulating acupuncture points, with needle placement conducted via teleoperation, and endpoint deviation manually measured. Ten repeated trials were performed per location. Latency was evaluated using motion capture, and operator cognitive load assessed via adapted NASA-TLX scales.
B. Performance
- Positional Repeatability: Across all test points and operators, mean placement deviation was within \pm\2.5 mm, aligning with the detection threshold for needle placement in simulated skin.
- System Latency: Round-trip latency (from master actuation to slave response) averaged 45 ms per axis, well within reported usability thresholds in surface teleoperation tasks[2].
- Operator Feedback: Users noted the system’s intuitive control mapping, low cognitive burden, and effective separation of spatial and insertional tasks—a benefit recognized in dual-master frameworks[1].
While the open-loop nature results in some error accumulation during prolonged operation, the 0.5× scaling greatly reduced gross motor overshoot and improved user confidence, validating position-scaling as a compensatory strategy for precision in simple actuation systems[7].
C. Discussion
Comparative analyses with recent research highlight the role of force and visual feedback for enhanced stability and safety in teleoperation[2][3][6]. Although haptic feedback and advanced controllers yield superior performance, especially in environments with unpredictable interaction forces or delays[7][8], open-loop systems with visual guidance alone remain valuable in specific educational, training, or cost-limited scenarios[4].
Notably, the inclusion of dual-master architecture and spatial scaling reflects ongoing trends in the field seeking to balance system complexity with real-world deployment needs[1][7]. Future enhancements could integrate low-cost tactile overlays[3], vision-based position correction, or low-complexity feedback algorithms[6] to approach the accuracy of advanced systems without sharply increasing cost or complexity.
Conclusion
We have demonstrated a robust, low-cost, dual-master, 4-DOF bilateral teleoperated robotic arm system tailored for simulated acupuncture. Utilizing open-loop control, scalable analog mapping, and accessible microcontroller integration, the architecture delivers effective positional accuracy and operator intuitiveness in the absence of advanced feedback modalities. While best suited for training, educational, or resource-constrained clinical applications, the modular design provides a compelling foundation for future upgrades incorporating tactile, visual, or autonomous overlays as demonstrated in contemporary teleoperation research[1][2][3].